Lenovo TD200 - ThinkServer - 3809 Hardware Maintenance Manual page 43

Hardware maintenance manual
Hide thumbs Also See for TD200 - ThinkServer - 3809:
Table of Contents

Advertisement

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 8 "Parts listing, TD200 Machine Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836" on page
257 to determine which components are customer replaceable units (CRU) and which components are
field replaceable units (FRU).
• If an action step is preceded by "(Trained service technician only)," that step must be performed only by
a trained service technician.
The Processor CPU nStatus has
Failed with FRB1/BIST condition.(n
= microprocessor number)
The Processor CPU nStatus has
a Configuration Mismatch.(n =
microprocessor number)
Error
A processor failed -
FRB1/BIST condition has
occurred.
Error
A processor configuration
mismatch has occurred.
1. Check for a server firmware
update.
Important: Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code
is supported for the cluster
solution before you update the
code.
2. Make sure that the installed
microprocessors are
compatible with each
other (see "Installing a
microprocessor and heat sink"
on page 189 for information
about microprocessor
requirements).
3. (Trained service technician
only) Reseat microprocessor n.
4. (Trained service technician
only) Replace microprocessor
n.
(n = microprocessor number)
1. Make sure that the installed
microprocessors are
compatible with each
other (see "Installing a
microprocessor and heat sink"
on page 189 for information
about microprocessor
requirements).
2. (Trained service technician
only) Replace the incompatible
microprocessor.
.
Chapter 5
Diagnostics
35

Advertisement

Table of Contents
loading

Table of Contents