12. Remove the air baffle (see "Removing the air baffle" on page 147).
13. Remove the front fan cage assembly (see "Removing the fan cage assembly" on page 149).
14. Connect the configuration signal cable. See "Power and signal cables for internal drives" on page 182 for
information about cabling the power and signal cables.
15. Complete the cabling of the ServeRAID-MR10i adapter. See "Power and signal cables for internal drives"
on page 182 for additional information about cabling the power and signal cables.
• For the eight drive-bay, 2.5 inch server model, connect one end of the signal cable to the drive
backplane for drive bays 0 through 3 and route the other end through the plastic slot on the bottom
of the chassis underneath the front fan cage; then, connect it to the ServeRAID-MR10i SAS/SATA
controller as shown in the following illustrations: