Lenovo TD200 - ThinkServer - 3809 Hardware Maintenance Manual page 186

Hardware maintenance manual
Hide thumbs Also See for TD200 - ThinkServer - 3809:
Table of Contents

Advertisement

• Inspect the drive tray for signs of damage.
• To maintain proper system cooling, do not operate the server for more than 10 minutes without either a
drive or a filler panel installed in each drive bay.
• You do not have to turn off the server to install hot-swap drives in the hot-swap drive bays.
To install a 3.5–inch hot-swap hard disk drive, complete the following steps.
Step 1.
Remove the EMC shield, if one is present.
Step 2.
Touch the static-protective package that contains the drive to any unpainted metal surface on the
server; then, remove the drive from the package and place it on a static-protective surface.
Step 3.
Make sure that the drive tray handle is in the open position.
Step 4.
Align the drive assembly with the guide rails in the bay; then, carefully slide the drive assembly into
the drive bay until the drive snaps into place.
1
Hot-swap hard disk drive
2
Drive tray
3
Drive tray handle (in open position)
4
EMC shield
Step 5.
Rotate the drive tray handle to the closed position.
Step 6.
Check the hard disk drive status indicator to make sure that the hard disk drive is operating
correctly.
After you replace a failed hard disk drive, the green activity LED flashes as the disk spins up. The
amber LED turns off after approximately 1 minute. If the new drive starts to rebuild, the amber LED
flashes slowly, and the green activity LED remains lit during the rebuild process. If the amber LED
remains lit, see Chapter 5 "Diagnostics" on page 21.
Note: You might have to reconfigure the disk arrays after you install hard disk drives.
Step 7.
Close the bezel.
Step 8.
Lock the side cover.
178
ThinkServer TD200 Hardware Maintenance Manual

Advertisement

Table of Contents
loading

Table of Contents