Lenovo TD200 - ThinkServer - 3809 Hardware Maintenance Manual page 131

Hardware maintenance manual
Hide thumbs Also See for TD200 - ThinkServer - 3809:
Table of Contents

Advertisement

Table 4. DSA Preboot messages (continued)
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 8 "Parts listing, TD200 Machine Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836" on page
257 to determine which components are customer replaceable units (CRU) and which components are
field replaceable units (FRU).
• If an action step is preceded by "(Trained service technician only)," that step must be performed only by
a Trained service technician.
• Go to the Lenovo support Web site at http://www.lenovo.com/support/ to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Message
number
Component Test
405-904-xxx BroadCom
Ethernet
Device
State
Test Interrupt
Failed
Description
Action
1. Make sure that the component
firmware is at the latest level.
The installed firmware level is
shown in the DSA event log in
the Firmware/VPD section for this
component. For more information,
see "Updating the firmware" on
page 306.
2. Run the test again.
3. Check the interrupt assignments
in the PCI Hardware section of
the DSA event log. If the Ethernet
device is sharing interrupts, if
possible, use the Setup utility see
"Starting the Setup Utility" on page
294) to assign a unique interrupt to
the device.
4. Replace the component that is
causing the error. If the error is
caused by an adapter, replace
the adapter. Check the PCI
Information and Network Settings
information in the DSA event log to
determine the physical location of
the failing component.
5. If the failure remains, go to
the Lenovo Web site for more
troubleshooting information at
http://www.lenovo.com/support.
123
.
Chapter 5
Diagnostics

Advertisement

Table of Contents
loading

Table of Contents