Battery
4
Connector for battery carrier
b. Press the battery carrier into the connector on the ServeRAID adapter until it is firmly connected.
c. Secure the battery carrier to the ServeRAID adapter with the screws that came with the battery pack.
9. Turn the ServeRAID-MR10i adapter so that the ServeRAID-MR10i adapter keys align correctly with the
connector.
Attention: Incomplete insertion might cause damage to the system board or the ServeRAID-MR10i
adapter.
1
ServeRAID-MR10i controller
2
PCI slot 1
10. Press the ServeRAID-MR10i adapter firmly into the connector on the system board.
11. Rotate the power-supply cage assembly out of the chassis. Lift up the power-supply cage handle and
pull the power-supply cage assembly all the way up until the retainer latch locks the cage in place
on the chassis.
.
Chapter 7
Installing and replacing FRUs