• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 8 "Parts listing, TD200 Machine Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836" on page
257 to determine which components are customer replaceable units (CRU) and which components are
field replaceable units (FRU).
• If an action step is preceded by "(Trained service technician only)," that step must be performed only by
a trained service technician.
• Go to the Lenovo support Web site at http://www.lenovo.com/support/ to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Error code
Description
3058001
System configuration invalid
3058004
Three boot failure
3108007
System configuration restored to default
settings
3138002
Boot configuration error
3808000
IMM communication failure
30
ThinkServer TD200 Hardware Maintenance Manual
Action
1. Run the Setup utility, and select Save Settings.
2. Run the Setup utility, select Load Default Settings,
and save the settings.
3. Reseat the following components one at a time in
the order shown, restarting the server each time:
a. Battery
b. Failing device (if the device is a FRU, then it
must be reseated by a trained service technician
only)
4. Replace the following components one at a time, in
the order shown, restarting the server each time:
a. Battery
b. Failing device (if the device is a FRU, then it
must be replaced by a trained service technician
only)
c. (Trained service technician only) System board
1. Undo any recent system changes, such as new
settings or newly installed devices.
2. Make sure that the server is attached to a reliable
power source.
3. Remove all hardware that is not listed on the
ThinkServer ready Web site.
4. Make sure that the operating system is not
corrupted.
5. Run the Setup utility, save the configuration, and
then restart the server.
Information only. This is message is usually associated
with the CMOS battery clear event.
1. Remove any recent configuration changes made
to the Setup utility.
2. Run the Setup utility, select Load Default Settings,
and save the settings.
1. Remove power from the server for 30 seconds, and
then reconnect the server to power and restart it.
2. Update the IMM firmware to the latest level (see
"Updating the firmware" on page 306).
3. Make sure that the virtual media key is seated and
not damaged.
4. (Trained service technician only) Replace the
system board.