Defining trunk module types and settings
Table 12 Module record values (Continued)
Attribute
Value
Clock Source Primary,
Secondary, Timing
Master
Designates whether the DTM/BRI acts as a primary or secondary timing slave or as a
Timing Master.
Note: A BRI module can be programmed with primary/secondary clock source, however, it
is recommended that a BRI module always be Timing Master if a DTM exists on the system
to be the Primary clock source.
*BRI clock source is set on the Services, Loops, Loop XXX screen. Refer to
T-loops (T1 profiles)" on page 279
For more information, see
Send Name
Y, N
Display
When set to Y, the system sends a specified outgoing name display (OLI) from the calling
telephone.
Appears only for Protocols: SL-1, NI-2, DMS100, DMS250, or PRI QSIG.
*BRI QSIG Send Name Display is set on the Services, Loops, Loop XXX screen. Refer to
"Identifying BRI T-loops (ETSI, QSIG)" on page
Remote
Y, N
Capability
MWI
This setting allows you to indicate MWI compatibility on the specific loop(s) that you are
using to connect to the central voice mail system on a Meridian 1 which has the MWI
package installed, with the RCAP setting set to MWI.
Appears only for SL-1 protocol.
Max Transits Default: 31
Indicate the maximum number of times that a call will be transferred within the SL-1 network
before the call is dropped. Protocol must be set to SL-1 to display this field.
Host node
M1, Embark, IDPX,
DSM
DPNSS cards connected to Embark switches have a different way of handling call
diversion, therefore, when you provision a DTM for DPNSS, you must indicate what type of
switch the lines are connected to.
When you select the Embark switch, calls are diverted using the Call Forwarding feature
instead of call diversion.
6
Press <TAB> to save the settings.
7
If your module is set to T1, PRI, or DASS2, refer to
page 150
to continue with the configuration.
8
After you have completed your module configurations, refer to
lines," on page 239
N0008589 3.3
Module/line type
T1
or
"Identifying BRI T-loops (ETSI, QSIG)" on page
"Determining Clock Sources for DTMs or BRIs" on page
to set up the lines the trunk modules will use.
*BRI
*BRI
PRI
S/T
U2
*BRI
PRI
QSIG
282.
PRI
PRI
"PRI Call-by-Call service selection" on
Chapter 9, "Configuring
*BRI
U4
DASS2
"Identifying BRI
282.
147.
DNPSS