Explaining the Media Bay Modules headings

Figure 36 Confirming the Programmed Bus Type

Programming tips: If the Actual Bus Type reads None, choose the correct setting in the
Programmed Bus Type field. After the system initializes to the module, the Actual Bus Type
should change to the correct module type. You may also have to disable, then re-enable the
module to force the system to re-initialize (under the Configuration menu). Refer to
Media Bay Module status" on page 159
Some modules take a few minutes to reinitialize.
If these actions do not cause the fields to display correctly, you may have a damaged module
or backplane. Try installing the module in a different media bay and retry the configuration.
Refer to the Installation and Maintenance Guide for your hardware for information about
removing and installing media bay modules.
4
The other headings on the Bus screen describe the current status of the modules, as described
in the following table.

Table 10 Bus XX record settings

Heading
Station module
Number of sets
Number of busy sets
State
N0008589 3.3
Value
Description
<digit>
This setting indicates the number of sets that are currently
attached to the module.
<digit>
This setting indicates the number of sets that are currently
using the module.
Enabled
This setting indicates the state of the module.
Disabled
Use the Configuration menu item to change this setting.
These fields must agree.
for details about enabling and disabling modules.