SRX210 Services Gateway Hardware Guide
Monitoring the SRX210 Services Gateway Using Chassis Alarm Conditions
118
When the services gateway detects an alarm condition, the alarm LED on the front panel
turns red or amber as appropriate.
To view a more detailed description of the cause of the alarm , issue the
CLI command.
alarms
For more information on the
Administration Guide.
Table 43 on page 118 describes alarms that can occur for an SRX210 Services Gateway
chassis component.
Table 43: SRX210 Services Gateway Chassis Alarm Conditions and
Corrective Actions
Component
Alarm Condition
Boot media
The services
gateway boots from
an alternate boot
device.
Mini-Physical
A Mini-PIM has
Interface
failed.
Module
(Mini-PIM)
command, see the Junos OS
show chassis alarms
Action
If the internal flash memory fails at startup,
the services gateway automatically boots
from the alternative boot device (USB
storage device).
NOTE: If you configured your services
gateway to boot from an alternative boot
device, ignore this alarm condition.
Reformat the internal flash memory, and
install a bootable image. (See the Junos
OS Administration Guide.)
If you did not configure the services
gateway to boot from an alternative boot
device, contact Juniper Networks Technical
Assistance Center (JTAC). See "Juniper
Networks Technical Assistance Center" on
page 122.
Contact the Juniper Networks Technical
Assistance Center (JTAC). See "Juniper
Networks Technical Assistance Center" on
page 122.
If you must replace the failed Mini-PIM, see
the SRX Series Services Gateways for the
Branch Physical Interface Modules
Hardware Guide for information about
replacing the Mini-PIMs.
Copyright © 2010, Juniper Networks, Inc.
show chassis
Alarm
Severity
Amber
(minor)
Red
(major)