Monitoring the SRX210 Services Gateway Power System

Copyright © 2010, Juniper Networks, Inc.
Table 43: SRX210 Services Gateway Chassis Alarm Conditions and
Corrective Actions (continued)
Component
Alarm Condition
Hardware
The services
components
gateway chassis
on the
temperature or
services
chassis is too warm.
gateway
The services
gateway fan has
failed.
The services
gateway
temperature is too
high, either because
of an internal
overheating
condition or because
the maximum
recommended room
temperature has
been exceeded.
Monitoring the SRX210 Services Gateway Chassis Using the CLI on page 113
Monitoring the SRX210 Services Gateway Components Using LEDs on page 115
Monitoring the SRX210 Services Gateway Power System on page 119
Using the Reset Config Button on the SRX210 Services Gateway on page 121
Changing the Reset Config Button Behavior on the SRX210 Services Gateway on page 121
Juniper Networks Technical Assistance Center on page 122
The LEDs on the services gateway enable you to determine the performance and
operation. The Power LED, located on the front panel of the services gateway, indicates
the different settings with respect to the power system.
Chapter 18: Monitoring the SRX210 Services Gateway
Action
Check the room temperature. See "SRX210
Services Gateway Specifications" on
page 7.
Check the airflow. See "General Site
Guidelines for Installing the SRX210
Services Gateway" on page 51.
Check the fans. See "SRX210 Services
Gateway Cooling System" on page 23.
If you must replace a fan, contact Juniper
Networks Technical Assistance Center
(JTAC). See "Juniper Networks Technical
Assistance Center" on page 122.
Use the CLI command
show chassis
to determine whether the fan is
environment
functioning normally.
If the fan has failed, contact JTAC. See
"Juniper Networks Technical Assistance
Center" on page 122.
The services gateway shuts down
automatically in 4 minutes.
Alarm
Severity
Amber
(minor)
Red
(major)
Red
(major)
119

Hide quick links: