TransAct POSjet 1500 Programmer's Manual page 202

Transact posjet 1500: software guide
Hide thumbs Also See for POSjet 1500:
Table of Contents

Advertisement

Codes and Commands
[ESC] [EM]p<n>
ASCII
[ESC] [EM] p<n>
Hexadecimal
1BH 19H 70H <n>
Decimal
<27> <25> <112><n>
IPCL
None
EPOS
None
Description
This command temporarily disables and enables the periodic status back feature if previously
activated with the [ESC][EM]P command.
Where
n = 0 disables PSB and n = (non zero) Enables PSB at the interval defined by the [ESC][EM]P
command.
If not previously activated with the [ESC][EM]P command, this command will activate it but not
save the value through a power cycle.
Where
n = Interval in 100 MS increments. IE 20 = 2 Seconds. Setting the value to 0 disables the feature.
Page 188
®
POSjet
1500
Rev M
Programmer' s Guide
Activate Periodic Status Back
Nov-07