BOMBARDIER Johnson 90 Service Manual page 19

Table of Contents

Advertisement

GENERAL INFORMATION
SERVIC E DATA - 90/115
ltem
Unlt
Data
90
115
ELECTRICAL
lgnition timing
Degrees at r/min
BTDC 1º-BTDC 44º
1
BTOC 3º - BTDC 44º
Ovar revolution limitar
rpm
6200
CKP sensor resistance
Q
at20ºC
168- 252
CMP sensor resistance
Q
at20ºC
-
lgnition coil resistance
Primary
Q
at20ºC
1.9- 2.5
Secondary
kil at 20ºC
No. 2-No. 3: 18-34 (lncluding H.T.cord and spark plug cap)
No. 1-No. 4: 19-36 (including H.T.cord and spar1( plug cap)
High tension cord resistance
kil/m at20ºC
Approx. 16
Battery charge coil resistance
Q
at20ºC
0.16-0.24
Battery charge coil output (12V)
A
40
Standard spark plug
Type
NGK
BKRSE
Gap
mm (in)
0.7-0.8 (0.028-0.031)
Fuse amp. rating
A
Main fuse: 60
Sub fusa: 30
Recommended battery capacity (12V)
Ah (kC)
12V 500 CCA (620 MCA) with 90 minute reserve capacity
Fuel injector resistance
Q
at20ºC
11.0-16.5
IAC valva resistance
Q
at20ºC
8-12
IAT sensor/ Cylinder temp. sensor/ Ex-
mani. temp. sensor (Thermistor
ill
al 25ºC
1.8-2.3
characteristic)
ECM main relay resistance
Q
at20ºC
80-120
Starter relay coil resistance
Q
at20ºC
80-120
PTT motor relay coil resistance
Q
at20ºC
3.0-4.5
STARTER MOTOR
Max. continuous time of use
Sec
30
Motor output
kW
1.4
Brush length
STO
mm(ln)
16.0 (0.63)
Limit
mm(in)
12.0 (0.47)
Commutator undercut
STO
mm(in)
0.5 - 0.8 (0.02 - 0.03)
Limit
mm (in)
0.2 (0.01)
Commutator outside
STO
mm (in)
29.0 (1.14)
diameter
Llmit
mm(in)
28.0 (1.10)
Commutator outside
STO
mm (in)
0.05 (0.002)
diameter difference
mm (in)
0.40 (0.016)
Limit
1-15

Advertisement

Table of Contents

Troubleshooting

loading

Related Products for BOMBARDIER Johnson 90

This manual is also suitable for:

Johnson 115Johnson 140

Table of Contents