ELECTRICAL
BATTERY CHARGING SYSTEM
lnspection
BATTERY CHARGE COIL
Measure battery charge coil resistance.
1ñioh
Digital tester
~
Tester range:
Q
(Resistance)
1. Disconnect battery charge coil leads from rectifier and
regulator.
2. Measure resistance between leads in the combinations
shown.
Battery charge coil resistance:
Terminal for tester probe
connection
Resistance
White
1
to White
2
White
2
to White
3
0.16-0.24
Q
White
3
to White
1
lf out of specification, replace battery charge coil.
FUSE CASE / FUSE
1®1
Digital tester
0~
Tester range: - ~ -(Continuity)
Fuse
1. Remove fuse from fuse case (or fuse terminal).
2. lnspect continuity between both terminals of fuse. lf no
continuity is exists, replace fuse.
Main fuse: 60A
Sub fuse: 30A
Main fuse terminal
lnspect continuity between terminal (A) and (8). lf no conti­
nuity is exists, replace fuse terminal and/or fuse.
Main fuse
Sub fuse
4-3