METER (+) LEAD
RED
(ring terminal)
(female terminal)
RED
RED/PURPLE
(ring terminal)
(female terminal)
RED
(ring terminal)
(ring terminal)
BLACK/RED
(ring terminal)
WHITE/GREY
(ring terminal)
TAN/BLACK
(ring terminal)
YELLOW/RED
(female terminal)
(ring terminal)
YELLOW/RED
(male terminal)
(ring terminal)
BLACK
(ring terminal)
(ring terminal)
Most of circuit can be tested with an ohmmeter
but a 100% test doesn't mean the MPEM is in
perfect condition.
-
CAUTION
Whenever connecting MPEM, always have
battery disconnected from circuit. If MPEM
must be connected when circuit is activated,
always connect BLACK/RED wire first to igni-
tion coil/CDI module to prevent wire from
touching solenoid positive terminal.
All Other Models
It is not possible to accurately check the MPEM
condition without specialized tools. Therefore, re-
place MPEM with a good known unit to conduct
testing.
NOTE: Before replacing the MPEM, make sure all
connectors are properly secured and there is no
water in connectors. Check also the signal and
power contacts in the AMP plug connectors. See
WIRING DIAGRAMS 14-01.
METER (-)
VALUE
RED
< 1Ω
< 1Ω
BLACK
> 20 kΩ
BLACK
> 10 kΩ
BLACK
> 100 kΩ
BLACK
> 200 kΩ
BLACK
> 10 kΩ
BLACK
> 50 kΩ
RED
> 10 kΩ
Section 08 ELECTRICAL SYSTEM
Subsection 02 (IGNITION SYSTEM)
Generating Coil Verification
717 Engine
STATIC TEST
Disconnect magneto wiring harness connector.
Install the 4-pin magneto harness adapter (P/N
295 000 131).
F01B28A
TYPICAL
Check resistance with a multimeter. Refer to the
following table for values and wire colors.
ADAPTER
PART NAME
WIRE
BLACK with
Generating coil
RED/BLACK
1
F01H5WA
1. Multimeter
2. Four-pin magneto harness adapter
3. RED/BLACK wire
4. BLACK wire
RESISTANCE
40-76 Ω
2
4
3
08-02-13