Table 3-1  Pin assignment of the M12 cable connector for PROFINET connector, ports 1 and 2
Pin
1
2
3
4
Thread
1
2
3
4
Thread
NOTE
When you deactivate the "Autonegotiation" function in STEP 7 , you must observe the differ­
ent assignment of the pins at X01 P1 R and X01 P2 R.
ET 200eco PN
Operating Instructions, 06/2022, A5E01250250-AN
Assignment
Assignment X01 P1 R
TXP
RXP
TXN
RXN
Functional earth FE
Assignment X01 P2 R
RXP
TXP
RXN
TXN
Functional earth FE