Configuration - Siemens SIMATIC Distributed I/O ET 200eco PN Operating Instructions Manual

Hide thumbs Also See for SIMATIC Distributed I/O ET 200eco PN:
Table of Contents

Advertisement

Technical specifications
Configuration without S7-PCT
Data for selection of an IO-Link device
Cable length, unshielded
Connection of IO-Link devices
Port type A
Port type B
Operating modes
IO-Link
DI
DQ
11.2.1

Configuration

Introduction
The IO-Link Master 4 IO-L 4×M12 has four ports. Each port is represented by a submodule.
Configuration of the IO-Link port of the IO-Link Master 4 IO-L 4×M12
You specify the various operating modes of each IO-Link port by configuring a relevant
submodule:
• as digital input by configuring a digital input submodule,
• as digital output by configuring a digital output submodule,
• as IO-Link device by configuring an IO-Link submodule.
• Port deactivated:
– In STEP 7 V5.5 and higher and with GSD: By deleting the submodule,
– in STEP 7 (TIA Portal): By deactivating the port enable.
The IO-Link ports are preconfigured as 2I + PQI.
ET 200eco PN
Operating Instructions, 06/2022, A5E01250250-AN
11.2 IO-Link Master (6ES7148-6JD00-0AB0)
supported; autostart function
Max. 20 m
Yes; with 3-wire cable
Yes; additional device supply: Max. 2 A per Port,
max. 4 A per module
Yes
Yes
Yes; max. 100 mA
IO-Link Master