Table 20: Sonet/Sdh Interface Alarm Messages - Juniper M40E Hardware Manual

Multiservice edge router
Hide thumbs Also See for M40E:
Table of Contents

Advertisement

M40e Multiservice Edge Router Hardware Guide

Table 20: SONET/SDH Interface Alarm Messages

CLI Message
interface-name so-x/x/x - SONET bit error rate defect
interface-name so-x/x/x - SONET bit error rate fault
interface-name so-x/x/x - SONET line AIS
interface-name so-x/x/x - SONET line remote defect indicator
interface-name so-x/x/x - SONET loss of frame
interface-name so-x/x/x - SONET loss of light
interface-name so-x/x/x - SONET loss of pointer
interface-name so-x/x/x - SONET loss of signal
interface-name so-x/x/x - SONET path AIS
interface-name so-x/x/x - SONET path mismatch
interface-name so-x/x/x - SONET path remote defect indicator
interface-name so-x/x/x - SONET PLL lock
interface-name so-x/x/x - SONET remote error indicator
interface-name so-x/x/x - SONET severely errored frame
interface-name so-x/x/x - SONET unequipped
Related
Documentation
154
All manuals and user guides at all-guides.com
If an LED is lit indicating a problem with the PIC, issue the
3.
command to view a more detailed description of the alarm cause:
user@host>show chassis alarms
For a list of messages that can appear in the output, see Table 20 on page 154.
If you are unable to correct the problem, replace the PIC with a spare. For instructions,
4.
see "Replacing a PIC in an M40e Router" on page 198. If the LEDs light correctly on the
spare, the original PIC is faulty. Return it to Juniper Networks for replacement, as
described in "Contacting Customer Support" on page 307.