Table 18: M40E Chassis Alarm Messages; Table 19: M40E Sonet/Sdh Interface Alarm Messages - Juniper M40E Hardware Manual

Multiservice edge router
Hide thumbs Also See for M40E:
Table of Contents

Advertisement

M40e Multiservice Edge Router Hardware Guide
148
All manuals and user guides at all-guides.com

Table 18: M40e Chassis Alarm Messages

Component
LCD Message
Fans and
Fan Failure
impellers
Fan Removed
Fans Missing
Temperature
Temperature Warm
sensors
Temperature Hot
Sensor Failure
Power supplies
PEM pem-ID Removed
PEM pem-ID High Temp
PEM pem-IDOutput Fail
PEM pem-ID Input Fail
SFMs
SFM sfm-number Failure
SFM sfm-number
Removed
Host modules
Host host-number
Failure
Host host-number
Removed
Craft interface
Craft Failure

Table 19: M40e SONET/SDH Interface Alarm Messages

LCD Message
interface-name so-x/x/x BERR-SD
interface-name so-x/x/x BERR-SF
interface-name so-x/x/x LAIS
interface-name so-x/x/x LOF
interface-name so-x/x/x LOL
CLI Message
RED ALARM - fan name Failure
YELLOW ALARM - fan name Removed
RED ALARM - Too many fans missing or failing
YELLOW ALARM - Temperature Warm
RED ALARM - Temperature Hot
RED ALARM - Temperature sensor failure
YELLOW ALARM - PEM pem-ID Removed
RED ALARM - PEM pem-ID High Temperature
RED ALARM - PEM pem-ID Output Failure
RED ALARM - PEM pem-ID Input Failure
RED ALARM - SFM sfm-number Failure
only if no alternate SFM is housed in chassis)
RED ALARM - SFM sfm-number Removed
only if no alternate SFM is housed in chassis)
RED ALARM - Host host-number Failure
RED ALARM - Host host-number Removed
YELLOW ALARM - Craft Failure
CLI Message
interface-name so-x/x/x - SONET bit error rate defect
interface-name so-x/x/x - SONET bit error rate fault
interface-name so-x/x/x - SONET line AIS
interface-name so-x/x/x - SONET loss of frame
interface-name so-x/x/x - SONET loss of light