Copyright © 2010, Juniper Networks, Inc.
All manuals and user guides at all-guides.com
see "Preventing Electrostatic Discharge Damage to an M Series, MX Series, or T Series
Router" on page 232.
Label the cable connected to the SFP so that you can later reconnect it to the correct
3.
SFP.
Disconnect the cable from the SFP. Immediately cover the transceiver and the end
4.
of the cable with a rubber safety cap.
WARNING: Do not look directly into a fiber-optic transceiver or into the
ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable
connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when
inserting or removing cable. The safety cap keeps the port clean and
prevents accidental exposure to laser light.
Arrange the cable in the cable management system to prevent it from dislodging or
5.
developing stress points. Secure the cable so that it is not supporting its own weight
as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop in
the cable management system. Placing fasteners on the loop helps to maintain its
shape.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend
radius. An arc smaller than a few inches in diameter can damage the cable
and cause problems that are difficult to diagnose.
Pull the ejector handle away from the SFP faceplate to unseat the SFP from the PIC.
6.
Pull the SFP out of the PIC and place it on the antistatic mat or in the electrostatic
bag.
CAUTION: After removing a transceiver from the chassis, wait at least 30
seconds before reinserting it or inserting a transceiver into a different slot.

Figure 115: Small Form-Factor Pluggable (SFP)

Connector
Locking pin
Chapter 16: Replacing M40e Hardware Components
209