Appendix C M40E Router Environmental Specifications; M40E Router Environmental Specifications; Table 26: M40E Router Environmental Tolerances - Juniper M40E Hardware Manual

Multiservice edge router
Hide thumbs Also See for M40E:
Table of Contents

Advertisement

APPENDIX C
M40e Router Environmental
Specifications

M40e Router Environmental Specifications

Copyright © 2010, Juniper Networks, Inc.
All manuals and user guides at all-guides.com
M40e Router Environmental Specifications on page 271
Table 26 on page 271 specifies the environmental conditions required for normal router
operation. In addition, the site should be as dust-free as possible. Dust can clog air intake
vents and filters, reducing cooling system efficiency. Check the filters and vents frequently,
cleaning them as necessary. For more information, see "Routine Maintenance Procedures
for the M40e Router" on page 129.

Table 26: M40e Router Environmental Tolerances

Description
Altitude
Relative humidity
Temperature
Seismic
Maximum thermal output
Tolerance
No performance degradation to 10,000 ft (3048 m)
Normal operation ensured in relative humidity range of 5% to 90%,
noncondensing
Normal operation ensured in temperature range of 32°F to 104°F
(0°C to 40°C)
Tested to meet Telcordia Technologies Zone 4 earthquake
requirements
AC power: 9350 BTU/hour (2738 W)
DC power: 8350 BTU/hour (2445 W)
271

Advertisement

Table of Contents
loading

Table of Contents