Storing An M40E Fpc; Figure 75: Holding An Fpc Horizontally - Juniper M40E Hardware Manual

Multiservice edge router
Hide thumbs Also See for M40E:
Table of Contents

Advertisement

M40e Multiservice Edge Router Hardware Guide
Related
Documentation

Storing an M40e FPC

138
All manuals and user guides at all-guides.com

Figure 75: Holding an FPC Horizontally

Holding an M40e FPC Overview on page 133
FPC LEDs and Controls on the M40e Craft Interface on page 38
M40e FPCs Supported on page 17
Replacing an FPC in an M40e Router on page 191
M40e Flexible PIC Concentrators (FPCs) Description on page 13
When not installed in the routing platforms, FPCs must be either stored in the container
in which a spare FPC is shipped or stored horizontally and component-side up on a flat,
stable surface.
When you store an FPC on a horizontal surface or in the shipping container, always place
it inside an antistatic bag. Because the FPC is heavy and because antistatic bags are
fragile, inserting the FPC into the bag is easier with two people. To do this, one person
holds the FPC in the horizontal position with the faceplate facing the body, and the other
person slides the opening of the bag over the FPC connector edge. If you must insert the
FPC into a bag by yourself, first lay the FPC horizontally on a flat, stable surface,
component-side up. Orient the FPC with the faceplate facing you. Carefully insert the
FPC connector edge into the opening of the bag, and pull the bag toward you to cover
the FPC.
CAUTION: To prevent damage when storing FPCs, observe the following
precautions:
Never lay an FPC component-side down.
Copyright © 2010, Juniper Networks, Inc.