Installing the Compaq ProLiant 5000R Server

Upgrading From the Hard Drive

If the system partition already has been upgraded with the latest version of the
Compaq System Configuration Utility, complete the following steps.
1. Restart the server by turning the power OFF, then ON. A system cycle
is required for ROMPaq to reprogram the system ROM.
2. Press the F10 key when the following prompt appears at the top of the
screen during POST.
Press "F 9" key for ROM-Based Diagnostics
Press "F10" key for System Partition Utilities
IMPORTANT:
or F10 during this time, you must reboot the server.
3. From the main menu, select Diagnostics and Utilities, then select
Upgrade Firmware. Press Enter to continue at the ROMPaq welcome
screen.
4. Select the device to be programmed, then the firmware image to be
programmed.
5. Press Enter to confirm the firmware reprogramming.
6. When all devices are programmed, press Escape.
7. Turn the power, then back ON. A power cycle is required for ROMPaq
to reprogram the system ROM.
Writer: Compaq Project: Installing the Compaq ProLiant 5000R Server Comments:
The text appears for only two seconds. If you do not press either F9
File Name: G-ch3.doc Last Saved On: 4/18/97 5:14 PM