Automatic Server Recovery
Base Memory Parity Error
Automatic Server Recovery
Extended Memory Parity Error
Automatic Server Recovery
Memory Parity Error
Automatic Server Recovery Reset
Limit Reached
Error Detected On Boot Up
Diagnostic Error
NMI - PCI Bus Parity Error
NMI - Expansion Board Error
NMI - Expansion Bus Master
Time-Out
Table 10-1
Critical Error Log Error Messages
Error Message
The system detected a data error in base memory
following a reset due to the Automatic Server
Recovery (ASR-2) Timer expiration.
The system detected a data error in extended
memory following a reset due to the ASR-2 Timer
expiration.
The system ROM was unable to allocate enough
memory to create a stack. Then, it was unable to put
a message on the screen or continue booting the
server.
The maximum number of system resets due to the
ASR-2 timer expiration has been reached, resulting in
the loading of Compaq Utilities.
The server detected an error during the Power-On
Self-Test.
An error was detected by the Diagnostics utility.
Refer to the specific error code in this chapter for a
detailed explanation.
A parity error was detected on the PCI bus.
A board on the expansion bus indicated an error
condition, resulting in a server failure.
A bus master type expansion board in the indicated
slot did not release the bus after its maximum time,
resulting in a server failure.