Error Messages
ACCELERATOR BOARD NOT
DETECTED
ACCELERATOR ERROR LOG
ACCELERATOR PARITY
READ ERRORS: N
ACCELERATOR PARITY
WRITE ERRORS: N
ACCELERATOR STATUS:
PERMANENTLY DISABLED
Table 11-2
DAAD Diagnostic Messages
The IDA-2 board did not detect the presence of a configured
array accelerator board. Install an array accelerator board
onto the IDA-2 controller. If you have an array accelerator
board installed, check the seating to ensure that it has been
properly installed onto the IDA-2 board. You may need to run
the Compaq System Configuration Utility and disable the array
accelerator board to get this message off the screen.
This is a list of the last 32 parity error lists on transfers
between the IDA-2 board transfer buffer and memory on the
array accelerator board. The starting memory address,
transfer count, and operation (read and write) displays. If
there are a number of these parity errors, you may need to
replace the array accelerator board.
This message displays the number of times that read memory
parity errors were detected during transfers between the IDA-
2 board transfer buffer and memory on the array accelerator
board. If there are a number of these parity errors, you may
need to replace the array accelerator board.
This message displays the number of times that write
memory parity errors were detected during transfers between
the IDA-2 board transfer buffer and memory on the array
accelerator board. If there are a number of these parity errors,
you may need to replace the array accelerator board.
The array accelerator board has been permanently disabled. It
will remain disabled until it is reinitialized using the System
Configuration Utility. Check the Disable Code field. Run the
System Configuration Utility to reinitialize the array
accelerator board.
Writer: Project: Diagnostic Tools Comments:
File Name: O-ch11.doc Last Saved On: 4/22/97 1:11 PM
Possible Corrective Action
Compaq ProLiant 5000 Servers Reference Guide
11-39
continued