1. Flexible cord must be <HAR> Type HO5VV-F, 3-conductor, 1.0 mm
conductor size. Power cord set fittings (appliance coupler and wall
plug) must bear the certification mark of the agency responsible for
evaluation in the country where it will be used.
2. Flexible cord must be Type SJT or equivalent, No. 16 AWG for
ProLiant 5000 models, 3-conductor. Wall plug must be a two-pole
grounding type with a NEMA 5-15P (15A, 125V) or NEMA 6-15P
(15A, 250V) configuration.
3. Appliance coupler, flexible cord, and wall plug must bear a "T" mark
and registration number in accordance with the Japanese Dentori Law.
Flexible cord must be Type VCT or VCTF, 3-conductor, 1.0 mm
conductor size. Wall plug must be a two-pole grounding type with a
Japanese Industrial Standard C8303 (15A, 125V) configuration.
Writer: Project: Power Cord Set Requirements Comments:
File Name: S-appb.doc Last Saved On: 4/22/97 1:19 PM
2
2
Compaq ProLiant 5000 Servers Reference Guide