11-18
Diagnostic Tools
POST Error Messages
Error Code
1789-Drive Not
Responding, Physical
Drive
Check cables or
replace physical drive
X.
Select "F1" to
continue - drive array
will remain disabled.
Select "F2" to fail
drive(s) that are not
responding -
Interim Recovery
Mode will be enabled
if configured for fault
tolerance.
1790-Disk 0 Error
1790-Disk 0
Configuration Error
1791-Disk 1 Error
* L= Long
S = Short
d
Continue
Audible
Beeps*
None
Cable or hard drive failure.
None
Hard drive error or wrong
drive type
None
Hard drive error or wrong
drive type
None
Hard drive error or wrong
drive type.
Writer: Project: Diagnostic Tools Comments:
File Name: O-ch11.doc Last Saved On: 4/22/97 1:11 PM
Probable Source of
Problem
1. Check the cable
connections.
2. If cables are
connected, replace the
drive.
3. If you do not want
to replace the drives
now, press F2.
Run the System
Configuration Utility.
Run the System
Configuration Utility
and Diagnostics.
Run the System
Configuration Utility
and Diagnostics.
Action