11-16
Diagnostic Tools
POST Error Messages
Error Code
1786-Drive Array
Recovery Needed
The following drive(s)
need Automatic Data
Recovery: Drive X.
Select "F1" to
continue with
recovery of data to
drive(s). Select "F2"
to continue without
recovery of data to
drive(s).
1787-Drive Array
Operating in Interim
Recovery Mode.
Physical drive
replacement needed:
Drive X
* L= Long
S = Short
Continued
Audible
Beeps*
None
Interim Data Recovery
mode. Data has not been
recovered yet.
None
Hard drive X failed or
cable is loose or defective.
Following a system restart,
this message reminds you
that drive X is defective
and fault tolerance is
being used.
Writer: Project: Diagnostic Tools Comments:
File Name: O-ch11.doc Last Saved On: 4/22/97 1:11 PM
Probable Source of
Problem
Press F1 key to allow
Automatic Data
Recovery to begin.
Data will automatically
be restored to drive X
now that the drive has
been replaced or now
seems to be working.
-Or-
Press the F2 key and
the system will
continue to operate in
the Interim Data
Recovery mode.
Replace drive X as
soon as possible.
A loose or defective
cable also may cause
this error.
Action