11-12
Diagnostic Tools
POST Error Messages
Error Code
1766- Slot x Drive Array requires System ROM Upgrade. Run
Systems ROMPaq Utility
1767- Slot x Drive Array Option ROM is Not Programmed
Correctly or may Conflict with the Memory Address Range of an
ISA Card. Check the Memory Address Configuration of installed
ISA Card(s) or run Options ROMPaq Utility to attempt SMART-2/E
Option ROM Reprogramming.
1768-Slot x Drive
Array - Resuming
logical drive
expansion process
* L= Long
S = Short
continued
Audible
Beeps*
None
SMART-2 Controller error
Writer: Project: Diagnostic Tools Comments:
File Name: O-ch11.doc Last Saved On: 4/22/97 1:11 PM
Probable Source of
Problem
Run the latest Systems
ROMPaq Utility to
upgrade your
System ROMs.
Remove or reconfigure
conflicting ISA cards,
especially any cards
that are not recognized
by the System
Configuration Utility.
Try reprogramming the
SMART-2/E
Controller's ROMs
using the latest
Options ROMPaq
(version 2.29 or
higher). Call customer
support if this does
not help.
No action required.
Appears whenever a
controller reset or
power cycle occurs
while array expansion
is in progress.
Action