Compaq ProLiant 5000 Reference Manual page 203

Hide thumbs Also See for ProLiant 5000:
Table of Contents

Advertisement

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11-40
Diagnostic Tools
DAAD Diagnostic Messages
Error Messages
ACCELERATOR STATUS:
POSSIBLE DATA LOSS IN
CACHE
ACCELERATOR STATUS:
TEMPORARILY DISABLED
ACCELERATOR STATUS:
UNRECOGNIZED STATUS
ACCELERATOR STATUS:
VALID DATA FOUND AT
RESET
ACCELERATOR STATUS:
WARRANTY ALERT
BATTERY PACK X BELOW
REFERENCE VOLTAGE
BATTERY X NOT FULLY
CHARGED
BOARD NOT ATTACHED
Continued
Possible data loss was detected during power-up due to all of
the batteries being below the sufficient voltage level and no
presence of the identification signatures on the array
accelerator board. There is no way to determine if dirty or bad
data was in the cache and is now lost.
The array accelerator board has been temporarily disabled.
Check the Disable Code field.
A status returned from the array accelerator board that DAAD
does not recognize. Call your Authorized Compaq Reseller for
the latest copy of DAAD.
Valid data was found in the posted write memory at
reinitialization. The data will be flushed to disk. This is not an
error or data loss condition. No action needs to be taken.
A catastrophic problem has occurred with the array
accelerator board. Refer to the other messages on the
Diagnostics screen for the exact meaning of this message.
Replace the array accelerator board.
The indicated battery pack is below the required voltage
levels. Allow for sufficient time for the batteries to recharge
(36 hours). If the batteries have not recharged after 36 hours,
replace the battery pack.
The battery is not fully charged. If 75% of the batteries
present are fully charged, the array accelerator is fully
operational. If more than 75% of the batteries are not fully
charged, allow 36 hours to recharge them.
The IDA-2 board has been configured for use with an array
accelerator board, but one is currently not attached. Locate
the original array accelerator board and attach it to the IDA-2
board.