POST Error Messages
Error Code
1779-Drive Array
Controller detects
replacement drives
1780-Disk 0 Failure
1781-Disk 1 Failure
1782-Disk Controller
Failure
1784-Drive Array
Drive Failure, Physical
Drive
1785-Drive Array not
Configured
* L= Long
S = Short
d
Continue
Audible
Beeps*
None
Intermittent drive failure
and/or possible loss of
data.
None
Hard drive/format error.
None
Hard drive/format error
None
Hard disk drive circuitry
error
None
Defective drive and/or
cables
None
Configuration error
Writer: Project: Diagnostic Tools Comments:
File Name: O-ch11.doc Last Saved On: 4/22/97 1:11 PM
Probable Source of
Problem
If this message
appears and drive X
has not been replaced,
this indicates an
intermittent drive
failure. This message
also appears once
immediately following
drive replacement
whenever data must
be restored from
backup.
Run Diagnostics.
Contact your service
provider
Run Diagnostics.
Contact your service
provider
Run Diagnostics.
Contact your service
provider
Check for loose cables.
Run Diagnostics.
Contact your service
provider.
Run the System
Configuration Utility
and correct.