Compaq ProLiant 5000 Reference Manual page 183

Hide thumbs Also See for ProLiant 5000:
Table of Contents

Advertisement

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11-20
Diagnostic Tools
POST Error Messages
Error Code
1795-Drive Array -
Array Accelerator
Configuration Error.
Data does not
correspond to this
drive array. Array
Accelerator is
temporarily disabled.
1796-Drive Array -
Array Accelerator Not
Responding.
Array Accelerator is
temporarily disabled.
* L= Long
S = Short
Continued
Audible
Beeps*
None
This indicates that while
the system was in use,
power was interrupted
while data was in the
Array Accelerator memory.
The data stored in the
Array Accelerator does not
correspond to this drive
array.
None
Array Accelerator is
defective or has been
removed.
Writer: Project: Diagnostic Tools Comments:
File Name: O-ch11.doc Last Saved On: 4/22/97 1:11 PM
Probable Source of
Problem
1.
-Or-
2.
1.
2.
Action
Match the Array
Accelerator to the
correct drive
array.
Run the System
Configuration
Utility to clear the
data in the Array
Accelerator.
Check that the
Array Accelerator
is properly
seated.
Run the System
Configuration
Utility to
reconfigure the
Compaq IDA-2
without the Array
Accelerator.
continued

Advertisement