11-2
Diagnostic Tools
Error Code
A Critical Error
occurred prior to this
power-up
101-ROM Error
101-I/O ROM Error
102-System Board
Failure
104-ASR-2 Timer
Failure
162-System Options
Not Set
163-Time & Date Not
Set
164-Memory Size
Error
* L= Long
S = Short
Table 11-1
POST Error Messages
Audible
Beeps*
None
A catastrophic system
error, which caused the
server to crash, has been
logged.
1L,1S
System ROM checksum
None
Options ROM checksum
None
DMA, timers, etc.
None
System board failure
2S
Configuration incorrect
2S
Invalid time or date in
configuration memory.
2S
Configuration memory
incorrect
Writer: Project: Diagnostic Tools Comments:
File Name: O-ch11.doc Last Saved On: 4/22/97 1:11 PM
Probable Source of
Problem
Run the Diagnostics
Utility.
Contact your service
provider.
Contact your service
provider
Contact your service
provider.
Run the Diagnostics
Utility.
Run the System
Configuration Utility
and correct.
Run the SYSTEM
Configuration Utility
and correct.
Run the System
Configuration Utility
and correct.
Action
continued