POST Error Messages
Error Code
*1788-Incorrect Drive
Replaced: Drive X
Drive(s) were
incorrectly replaced:
Drive Y Select "F1" to
continue - drive array
will remain disabled.
Select "F2" to reset
configuration - all
data will be lost.
*NOTE : The 1788 error message might also be displayed inadvertently due to a bad power
cable connection to the drive or by noise on the data cable. If this message was due to a
bad power cable connection, but not due to an incorrect drive replacement, repair the
connection and press F2.
-Or-
If this message was not due to a bad power cable connection, and no drive replacement
took place, this could indicate noise on the data cable. Check cable for proper routing.
* L= Long
S = Short
d
Continue
Audible
Beeps*
None
Drives are not installed in
their original positions, so
the drives have been
disabled. See note below.
Writer: Project: Diagnostic Tools Comments:
File Name: O-ch11.doc Last Saved On: 4/22/97 1:11 PM
Probable Source of
Problem
Reinstall the drives
correctly as indicated.
Press F1 to restart the
computer with the
drive array disabled.
-Or-
Press F2 to use the
drives as configured
and lose all the data
on them.
Compaq ProLiant 5000 Servers Reference Guide
11-17
Action