Exhaust Pipe / Muffler Removal And Installation - Suzuki VLR1800 Service Manual

Table of Contents

Advertisement

1K-9 Exhaust System:
2) Measure the position sensor output voltage at fully
opened position.
EXCVA position sensor out put voltage
EXCV is fully opened: 3.6 ≤ Output voltage ≤ 4.55
V ((+) Y – (–) W)
3) If the measured voltage is more than specification,
adjust the No. 2 cable adjuster as follows:
a) Set the EXCVA to the adjustment position. Refer
to "EXCVA / EXCV Cable Removal and
Installation (Page 1K-4)".
CAUTION
!
Adjusting the No. 2 cable with the EXCV fully
opened can damage the EXCVA. Be sure to
adjust the No. 2 cable with the EXCV set in
adjustment position.
b) Turn out the No. 2 cable adjuster (1) in or out to
set the output voltage within the specified value.
1
4) After adjusting the EXCV cables, perform Step 2 to
confirm DTC "46" is not indicated.
(A)
(B)
I822H11B0023-01
I822H11B0024-01

Exhaust Pipe / Muffler Removal and Installation

Removal
1) Remove the right frame cover and EVAP canister.
Refer to "Exterior Parts Removal and Installation in
Section 9D (Page 9D-3)" and "Evaporative Emission
Control System Removal and Installation (Only for E-
33) in Section 1B (Page 1B-13)".
2) Remove the EXCVA mounting bolts.
3) Disconnect the O2 sensor lead wire couplers (1),
EXCVA position sensor coupler (2) and EXCVA
motor coupler (3).
1
4) Loosen the muffler connecting bolt (4).
B822H11B06002
I822H11B0025-01
1
3
2
I822H11B0026-01
4
I822H11B0027-01