Western Digital Ultrastar Serv60+8 User Manual page 337

Hide thumbs Also See for Ultrastar Serv60+8:
Table of Contents

Advertisement

User Guide
Note: When installing SSDs for this configuration, the preinstalled HDDs will have to be moved one
entire row to the next vacant row near the front of the enclosure.
Figure 444: Minimum HDD and Minimum SSD Partial Population
Minimum HDD and Maximum SSD Partial Population:
The enclosure supports a minimum of 24 HDDs and one SSD in the drive bay and a configuration of no SSDs
in the center channel for a partially populated enclosure. The enclosure can support a maximum of up to 24
total SSDs in this configuration. The center SSD channel supports a minimum configuration of no SSDs with
a maximum of eight SSDs. The center channel SSDs must be populated from the drive slots closest to the
rear IO first, starting with drive slot 67 and work backward. The remaining unpopulated center channel drive
slots must be populated with drive blanks until the center channel is full. The enclosure does not support a
mix of SAS and SATA drives. The image below details the required configuration for minimum HDD and
maximum SSD with the minimum SSD center channel configuration.