Western Digital Ultrastar Serv60+8 User Manual page 106

Hide thumbs Also See for Ultrastar Serv60+8:
Table of Contents

Advertisement

User Guide
b) Use the handle to pull evenly on the component to remove it from the enclosure.
Figure 115: Removing System Fans
12. Uninstall the rest of the system fans in the same manner as the first.
13. Uninstall server cover panel on both sides of the enclosure that contains the failed CPU and Heat Sink
module.
Note: The same steps to uninstall the server cover panel apply to both sides of the enclosure with
the exception of the number of screws that secure the server cover panel. From the rear of the
enclosure, the left panel contains two screws. The panel on the right side of the enclosure contains
one screw.
a) Remove the screws that secure the server cover panels to the chassis using a T7 Torx screwdriver.
Note: When at the rear of the enclosure, the left server cover panel contains two T7 Torx
screws. The left server cover panel contains only one T7 Torx screw.
Figure 116: Removing the Server Cover Panel Screws
4.8
106
4
Part Replacement
CPU and Heat Sink Module Replacement

Advertisement

Table of Contents
loading

This manual is also suitable for:

H4060-s

Table of Contents