Specification
Altitude
Table 2: Electrical Specifications
Specification
Max Power Consumption
Typical Power Consumption
Note: Max and Typical Power Consumption
values represent the output power to the
system. Input power will vary depending on
the PSU efficiency and load sharing between
PSUs
Input Voltage
PSU Connector Type
PSU Efficiency
Inrush Current Maximum (per PSU)
Typical Inrush Current (per PSU)
Caution: The Ultrastar Serv60+8 can only be plugged into highline. If the unit is plugged into lowline,
the PSU will report a "Critical" state when status pages are queried using SES. In this case, the enclosure
will power up, but the drives will not.
Table 3: Mechanical Specifications
Specification
Shock
Vibration
Weight
Dimensions with CMA
Length without CMA
Non-Operational
-300m to 12,000m / -984 ft. to 39,370 ft
Value
~2000W
~1800W
200 - 240 VAC
C14
80 PLUS Platinum
AC line inrush current shall not exceed 35A peak
measured per IPC-9592B(L) Appendix C-4.1.
15A
Non-Operational
10G, 0 - peak,11ms half sine; 3
positive and 3 negative pulses in each
axis shock
0.75G, 0 - peak swept sine; 5 -500Hz;
1 complete sweep @ 1/2 octave per
minute
95.25 kg / 210 lbs.
W: 447mm x L: 1197 mm x H: 175mm / W: 17.6in. x L: 47.13in.. x H:
6.89in.
1026 mm / 40.39in.
13
1.4
Ultrastar Serv60+8 Specification Summary
Operational
-300m to 3048m / -984 ft. to 10,000 ft.
Operational
5G, 0 - peak, 11ms half sine; 3
positive and 3 negative pulses in each
axis- minimum 6 seconds between
shocks to allow for write/read
recovery
0.10G,0 - peak swept sine; 5 -500Hz;
1 complete sweep @ 1/2octave per
minute
1