b) Use the handle to pull evenly on the component to remove it from the enclosure.
Figure 155: Removing System Fans
12. Uninstall the rest of the system fans in the same manner as the first.
13. Uninstall server cover panel on both sides of the enclosure that contains the failed Heat Sink.
Note: Uninstall the server cover panel on the side that requires the CPU replacement. The same
steps to uninstall the server cover panel apply to both sides of the enclosure with the exception
of the number of screws that secure the server cover panel. From the rear of the enclosure, the
left panel contains two screws. The panel on the right side of the enclosure contains one screw.
a) Remove the screws that secure the server cover panels to the chassis using a T7 Torx screwdriver.
Note: When at the rear of the enclosure, the left server cover panel contains two T7 Torx
screws. The left server cover panel contains only one T7 Torx screw.
Figure 156: Removing the Server Cover Panel Screws
135
4
Part Replacement
4.9
Heat Sink Replacement