Table 5-36. System Interconnect Uplink Ports - Western Digital ActiveScale X100 Installation Manual

Hide thumbs Also See for ActiveScale X100:
Table of Contents

Advertisement

ActiveScale™ X100 Installation Guide
• For uplink mode 1 (two individual 10G access ports (48,47) per System Interconnect):
– Connect transceivers to ports 48 and 47 on each System Interconnect, on each system, at each site.
• For uplink mode 2 (one 10G trunk port (48) per System Interconnect):
– Connect transceivers to port 48 on each System Interconnect, on each system, at each site.
• For uplink mode 3 (one 40G trunk port (50) per System Interconnect):
– Connect transceivers to port 50 on each System Interconnect, on each system, at each site.
• For uplink mode 4 (three 10G trunks ports (48,47,46) with LACP per System Interconnect):
– Provide non-conflicting VLAN IDs and configure your respective switch ports for LACP.
– Connect transceivers to ports 48, 47, and 46 on each System Interconnect, on each system, at each
site.
• For uplink mode 5 (two 40G trunks ports (52,50) with LACP per System Interconnect):
– Provide non-conflicting VLAN IDs and configure your respective switch ports for LACP.
– Connect transceivers to ports 52 and 50 on each System Interconnect, on each system, at each site.

Table 5-36. System Interconnect uplink ports

Local device
System Interconnect 1 (SW1)
System Interconnect 1 (SW1)
System Interconnect 2 (SW2)
System Interconnect 2 (SW2)
Figure 5-50. Uplinks illustrated
Local port
48
Site
_SystemNetwork1
N
47
Site
_Column1_StorageNetwork1
N
48
Site
_SystemNetwork2
N
47
Site
_Column1_StorageNetwork2
N