Front Outer Cutting Unit Lift Rate Adjustment
The #4 (left front) and #5 (right front) cutting unit lift cir-
cuit is equipped with a adjustable valve to ensure the
1
front cutting units lower evenly. Adjust cutting units as
follows:
1. Locate valve under seat.
2. Loosen setscrew on valve. Rotate valve clockwise to
slow down drop rate of front outside cutting units.
3. Verify lift rate adjustment by raising and lowering cut-
Figure 21
ting units several times. Readjust as required.
1. Cutting unit adjustment valve
4. After desired drop rate is attained, tighten set screw
to lock adjustment.