11. Remove the valve ring (Fig. 50). Remove and dis-
card the two seal rings (Fig. 51). The valve ring should
be free of nicks and scoring.
12. Remove the valve plate by lifting it from the isolation
manifold (Fig. 52).
13. Inspect the slot edges and ground surfaces. If the
valve plate shows nicks or scoring or the edges are not
sharp, it must be replaced.
NOTE: The valve ring and valve plate are a matched set
and must be replaced as a set.
Reelmaster 6500–D/6700–D
Page 4 – 71
Figure 50
Figure 51
Figure 52
Hydraulic System