22. Remove the drive link from the unit (Fig. 59).
23. Inspect each end of the drive link. the four crowned
contact surfaces should not be worn or scored. Replace
if wear or scoring is evident.
24. Remove the metering ring and discard the two seal
rings (Fig. 60). If the metering ring bore is scored, it
should be replaced.
25. The "metering package" components are held to-
gether with eleven hex socket head screws. Lift the me-
tering package from the assembly, and put it on a clean
surface (Fig. 61).
IMPORTANT: Do not clamp the metering package in
a vise, as this could damage the components.
Hydraulic System
Page 4 – 74
Figure 59
Figure 60
Figure 61