Mcs Microcontrollers - Kodak DryView 6800 Diagnostics Manual

Laser imager
Hide thumbs Also See for DryView 6800:
Table of Contents

Advertisement

DIAGNOSTICS
30JUL07

MCS MICROCONTROLLERS

8F2919
Page
16 of 326
Important
This test is not for the ROLLBACK AY or PICKUP AY. To test these MICROCONTROLLERS
see
TRAY
1
To test any of the MICROCONTROLLERS on the I
Diagnostics>MCS>MCS Diagnostics.
2
From the "Select Diagnostic" drop-down menu, select the type of test. The test types
include:
"Micro Controllers" - This diagnostic runs the same tests on the
MICROCONTROLLERS that are run normally during "self-test".
"Memory" - This diagnostic checks image memory by writing to the memory and then
reading it back.
"Reset" - This function resets the selected MICROCONTROLLER to the original
condition.
Note
If you select "Memory", from the "Cycle" drop-down menu, select if the test should be run for
"One Cycle" or "Continuous".
3
From the "Select Operation" drop-down menu, select the MICROCONTROLLER you want
to test:
Note
If you select either "Optics" or "Sorter" from the "Select Microcontroller" menu, you must set
the SERVICE SWITCH to the service position before running the test.
4
Click [Run].
Tests will run once (except if "Continuous" was selected) and display "Pass "or "Fail."
5
Click the bottom line of the screen to display test results data.
Diagnostics.
2
C bus, select
Using the Diagnostics

Advertisement

Table of Contents
loading

Table of Contents