3-1-9 Protective Function

The functional settings are not allowed to change without the input of a password.
When the protective function is set to "effective," the setting can be changed by inputting the password.
The setting contents monitor function can be used regardless of the protective function "effective / ineffective."
The password should be a 4-digit number from 0 to 9. (The password of the factory setting is "0000.")
The protective function is set on the receiver side.

3-1-10 Initialization Function

The settings can be initialized. (factory setting) (Note)
The factory setting of each function is as follows.
Fixed blanking function
Floating blanking function
Auxiliary output switching function
Emission intensity control function
Setting of the muting function on each beam channel
Muting setting
Muting input conditions
changing func-
Setting of the muting lamp diagnosis function (Ver. 2 or later)
tion
Muting sensor output operation setting (Ver. 2.1 only)
Interlock setting changing function
External devise monitor setting changing function

Override setting changing function (Ver. 2.1 only)

Note: The setting of the protective function and the setting data of the copy function are not initialized.

3-1-11 Setting Contents Monitoring Function

Each setting of the SF4B / SF4B<V2> series can be monitored. The following can be monitored.
Model No. / the number of beam channels
6HWWLQJ RI WKH ¿[HG EODQNLQJ IXQFWLRQ 5HDGLQJ RXW WKH UHFRUG RI WKH ODWHVW  WLPHV LV SRVVLEOH
6HWWLQJ RI WKH ÀRDWLQJ EODQNLQJ IXQFWLRQ 5HDGLQJ RXW WKH UHFRUG RI WKH ODWHVW  WLPHV LV SRVVLEOH
Setting of the auxiliary output switching function
Setting of the emission intensity control function
Setting of the muting setting changing function
(Reading out the record of the latest 5 times is possible, however, only for setting beam channel.)
Setting of the interlock setting changing function
Setting of the external device monitor setting changing function
Override setting changing function
3-1-12 Override Setting Changing Function (Ver. 2.1 only)
Maximum continuous effective time set at the override function can be changed.
The maximum continuous effective time can be set in the range of 60 to 600 sec. (in units of 10 sec.).
The factory setting is 60 sec.
© Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V
When the protecting function is set to "ineffective," the third person may change the set-
ting. It is recommended that the protecting function should be set to "effective" so as not
to change the setting by the third person.
7DNH VXI¿FLHQW FDUH QRW WR IRUJHW WKH VHW SDVVZRUG ,Q FDVH \RX IRUJHW WKH SDVVZRUG
please contact us.
Function
Functional Descriptions
Setting
Ineffective
Ineffective
Mode 0
Normal mode
Effective for all beam channels
A = B
Effective
NONO
Start / Restart
Effective / 300ms
60 sec.
16