Omron CJ1W-EIP21 Operation Manuals page 169

For nj-series cpu unit. cj-series ethernet/ip units
Hide thumbs Also See for CJ1W-EIP21:
Table of Contents

Advertisement

1
Set the same tag set names for the output and input tag sets for the connection. The tag set
names can also include forward and backward ellipses.
2
Select Auto Connection Configuration from the Network Menu. The connections will be set
automatically. A dialog box will appear to set forward and backward ellipses for both output and
input tag sets as soon as automatic connection setting processing has begun.
Input the ellipses and click the OK Button. Processing for automatic setting is started.
3
If there are tag sets that meet the conditions for automatic connection setting, they are dis-
played.
Click the OK Button. Processing for automatic setting is started.
CJ-series EtherNet/IP Units Operation Manual for NJ-series CPU Unit (W495)
7 Tag Data Link Functions
7
7-39