Omron CJ1W-EIP21 Operation Manuals page 122

For nj-series cpu unit. cj-series ethernet/ip units
Hide thumbs Also See for CJ1W-EIP21:
Table of Contents

Advertisement

5 Sysmac Studio Settings for the EtherNet/IP Unit
 Recognition 1
Setting
Recognition method
*2
IP address
Host name
Community name
 Recognition 2
Setting
Recognition method
*2
IP address
Host name
Community name
*1 These settings are required if the SNMP service is enabled.
*2 Due to Ethernet restrictions, you cannot specify the IP addresses that are described below.
• IP addresses that start with 127, 0, or 255 (decimal)
• Class-D IP addresses (224.0.0.0 to 239.255.255.255)
• Class-E IP addresses (240.0.0.0 to 255.255.255.255)
5-10
*1
Set the method to use to specify SNMP managers for which access is per-
mitted.
• IP address
• Host name
Make these settings to permit access by only certain SNMP managers.
Access is not allowed unless an IP address or host name is set.
Set the IP address of the SNMP manager.
If the default setting of 0.0.0.0 is used, access is permitted from all SNMP
managers.
(Set this setting if the recognition method in the recognition 1 settings is set
to the IP address Option.)
Set the host name of the SNMP manager.
(Set this setting if the recognition method in the recognition 1 settings is set
to the Host name Option.)
(You can use up to 200 single-byte alphanumeric characters, dots, and
hyphens with up to 63 single-byte alphanumeric characters between dots.)
Set the community name to enable the SNMP manager to access informa-
tion from the EtherNet/IP Unit.
(Single-byte alphanumeric characters, dots, and hyphens: 200 characters
max.)
*2
Set the method to use to specify SNMP managers for which access is per-
mitted.
• IP address
• Host name
Make these settings to permit access by only certain SNMP managers.
Access is not allowed unless an IP address or host name is set.
Set the IP address of the SNMP manager.
If the default setting of 0.0.0.0 is used, access is permitted from all SNMP
managers.
(Set this setting if the recognition method in the recognition 2 settings is set
to the IP address Option.)
Set the host name of the SNMP manager.
(Set this setting if the recognition method in the recognition 2 settings is set
to the Host name Option.)
(You can use up to 200 single-byte alphanumeric characters, dots, and
hyphens with up to 63 single-byte alphanumeric characters between dots.)
Set the community name to enable the SNMP manager to access informa-
tion from the EtherNet/IP Unit.
(Single-byte alphanumeric characters, dots, and hyphens: 200 characters
max.)
CJ-series EtherNet/IP Units Operation Manual for NJ-series CPU Unit (W495)
Description
Description
Default
IP address
0.0.0.0
None
public
Default
IP address
0.0.0.0
None
public

Advertisement

Table of Contents
loading

Table of Contents