Comparison Output Function

8.1.3 Configuration Using Tool Software

The setting of the comparison output function is specified in the configuration menu of FPWIN
GR7.
 Setting method
The following procedure describes the process when the multi I/O unit has been already
allocated in the I/O map. Set the "counter (for external input)" or "PLS/PWM output counter" to
be compared in advance. The counter can be set for each comparison output.
PROCEDURE
1. Select "Options" > "Multi I/O Unit Setting" in the menu bar.
The "Mufti I/O Unit Setting" dialog box will be displayed. Select a unit to be used.
2. Select "Comparison match output" from the "Selection of function" tree,
and double-click a comparison match number to which the comparison
output is allocated.
The "Comparison match output Advanced" dialog box will be displayed.
3. Check the box of "Compare".
4. Select a counter to be compared from the pull-down box.
Select High-speed counter (CH0-CH3) or PLS output (PLS0-PLS3).
5. Input the comparison condition and comparison value.
Select either "ON when elapsed value is smaller than setting value" or "ON when
elapsed value is larger than or equal to setting value" for the comparison
condition.
6. Select a comparison output destination.
Select either "External terminal / Internal I/O" or "Internal I/O".