Unit Memory Detailed Information (H Type); Common Area - Panasonic FP7 User Manual

Multi input/output unit
Hide thumbs Also See for FP7:
Table of Contents

Advertisement

Specifications

13.5 Unit Memory Detailed Information (H type)

13.5.1 Common Area

Unit
memory
Name
no.
(Hex)
UM 00200
Axis setting
Positioning repeat
UM 00201
count (CH0)
Positioning repeat
UM 00202
count (CH1)
Positioning repeat
UM 00203
count (CH2)
Positioning repeat
UM 00204
count (CH3)
UM 00204
Reserved for system
-UM 00206
UM 00207
Error code
UM 00208
Reserved for system
13-44
Default
Description
Stores used channels (axes) and usage methods.
Monitor using binary display.
bit no,
0
1
2
H0
3
7-4
8
9
15-10
Stores the repeat count in decimal when using the
U0
repeat control in the position control.
Setting value
U0
0 or 1
U0
2 to 254
U0
255 or more
-
-
Stores a generated positioning error code in Hex
format (hexadecimal) when using the pulse output
function (table setting mode).
H0
* The higher 8 bits indicate the channel number and
the lower 8 bits indicate the error code.
-
-
A: Available, -: Not available
Settings
Not use CH0 (0) / Use (1)
Not use CH1 (0) / Use (1)
Not use CH2 (0) / Use (1)
Not use CH3 (0) / Use (1)
Disable the setting
Not use CH0 and CH1 as
interpolation axes (0) / Use (1)
Not use CH2 and CH3 as
interpolation axes (0) / Use (1)
Disable the setting
Operation
Not repeat an operation.
Repeat an operation for a
specified number of times.
Repeat an operation infinitely.
R
W
A
A
A
A
A
A
A
A
A
A
-
-
A
A
-
-

Advertisement

Table of Contents

Troubleshooting

loading