Multi I/O Unit Setting
 Pulse output / PWM output (PLS0-PLS3 / PWM0-PWM3: Selectable by channel.)
Setting item
Function setting
Data update timing
Frequency
Duty
Counter elapsed value
Counter upper/lower limit
values
Pulse start logic (Except
PWM output)
 Positioning (CH0-CH3: Selectable by channel)
Setting item
Function setting
Counter elapsed value
Counter upper/lower limit
values
(Note): "Use (Use J point terminal)" is only for CH0 - CH1.
REFERENCE
For details of the pulse output/PWM output function, refer to page 9-2.
For details of the positioning function, refer to page 10-2.
5-12
Settings
Unused / PLS output - Direction distinction /
PLS output - Individual output / PLS output - Phase output /
PLS output - Comparison match stop / PWM output
When start signal rises
When start signal rises or when comparison output is performed
When start signal rises or when data is updated
For pulse output: 0 to 500000 (Settable by 1 Hz.)
For PWM output: 0 to 100000 (Settable by 1 Hz.)
0.0 to 100.0 (0.0% to 100.0%) (Only when using PWM output)
-2,147,483,648 to +2,147,483,647
-2,147,483,648 to +2,147,483,647
OFF start / ON start
Settings
Unused / Use / Use (Use J point terminal) (Note)
-2,147,483,648 to +2,147,483,647
-2,147,483,648 to +2,147,483,647