Panasonic FP7 User Manual page 83

Multi input/output unit
Hide thumbs Also See for FP7:
Table of Contents

Advertisement

7. Press the [OK] button.
The selected condition will be registered on the "Multi I/O Unit Setting" dialog box.
The following figure shows the example that the output compared to "High-speed
counter (Direction distinction)" is allocated to the output (Y100) of multi I/O unit.
The control input for monitoring is automatically allocated to the input (X110) of
the unit's internal I/O.
The set values will be effective when they are downloaded with programs or other
configuration information as a project.
Precautions when using FPWIN GR7 for configuration
• On the unit ver.1.0x, internal contacts cannot be set as the comparison output destination.
When selecting internal contacts as the comparison output destination on the tool software,
the registration of the comparison function is set not to be used.
REFERENCE
This function can also be set by writing to the comparison output setting
area of unit memories with user programs. For details of unit memories,
refer to "13.4.7 Comparison Output Setting Area".
8.1 Comparison Output Function
8-5